Journal of Chemical and Pharmaceutical Research (ISSN : 0975-7384)

header
Reach Us reach to JOCPR whatsapp-JOCPR +44 1625708989
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Original Articles: 2013 Vol: 5 Issue: 11

Voltammetric determination of potassium hydrogenperoxomonosulfate in pure substance and disinfectant "Ecocide S"

Abstract

The behavior of potassium hydrogenperoxomonosulfate (KHSO5) has been studied using alternating current voltammetry with square wave modulation in potential range +1.0…–1.2 V at carbositall electrode as indicating and auxiliary electrode (reference electrode Ag, AgCl/KСl(sat)) (Ep = +0.25 V). A linear relationship between peak current and concentration was obtained in the range 0.9´10–5 mol L–1 to 5.4´10–5 mol L–1 of the KHSO5 concentrations at pH ~ 0.8 for pure substance. It is Ip = (8.3 ± 0.6)´103´Ãƒâ€˜Ã‚ (r = 0.999). RSD were 2.68 %, 2.55 % and 2.39 % for the 3.6´10–5, 4.5´10–5 and 5.4´10–5 mol L–1concentrations of KHSO5 model solutions, respectively (δ = –0.28…+0.44 %). The addition method was used for KHSO5 determination in disinfectant "Ecocid S", RSD were 2.01 % and 1.88 % for с(KHSO5) = 4.65´10–5 and 7.75´10–5 mol L–1, respectively. The obtained results have good agreement with those obtained by using the reference method of iodometric titration, with an accuracy lower than – 0.42 %.