Journal of Chemical and Pharmaceutical Research (ISSN : 0975-7384)

header
Reach Us reach to JOCPR whatsapp-JOCPR +44 1625708989
All submissions of the EM system will be redirected to Online Manuscript Submission System. Authors are requested to submit articles directly to Online Manuscript Submission System of respective journal.

Original Articles: 2013 Vol: 5 Issue: 10

Chemical equivalence study on four brands of �Ž�±-methyldopa

Abstract

Substandard pharmaceutical products have a deleterious effect on health care delivery at all levels. The manufacturers of health products, the medical practitioners and the patients are all affected by substandard medicines but the patient is the worst hit. Methyldopa is an important anti-hypertensive agent used in the management of hypertension. The chemical equivalence of four brands of methyldopa was carried out using the United State Pharmacopoeia (USP) method, which involve non-aqueous titration. Three out of the four brands of methyldopa passed the test that is the percentage content fell within the specified range of 90-110% while one of the samples failed the test with percentage content of 82.07%. This finding points to the need for regular quality checks on pharmaceutical products in circulation.